Part Number Hot Search : 
25B45 FDG63 2412S 18F8720 A4016 BU508AF P6KE130 1117A
Product Description
Full Text Search
 

To Download MKS3P-2 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 General-purpose Relays
MK-S (New Models)
CSM_MK-S_DS_E_4_1
New Super MK Relays. Models with Latching Lever Added to the Series.
* Same mounting and internal wiring as the previous Super MK Relays * Built-in mechanical indicator enables checking contact operation. * Two modes can be used to check circuits for models with latching lever. * Nameplate provided on models with latching lever. * All materials are RoHS compliant. * UL and IEC (TUV) certification.
Features
Models with Latching Lever
Operation indicator * Nameplate Mechanical indicator Latching lever DC: Blue AC: Red
Yellow button
Operating Method for Latching Lever
Relay in Normal Operation For Momentary Operation For Lock Operation
* The operation indicator is built in only on specified models.
Example of Applications of Models with Latching Levers
Operation checks in relay sequence circuits
Model Number Structure
Model Number Legend MKS@@@@@-@-@
12345
1. Contact Form 2: DPDT 3: 3PDT 2. Terminals P: Plug-in 3. Mechanical Indicator/Test Button Blank: Mechanical indicator I: Mechanical indicator and lockable test button 4. LED Indicator Blank: Standard N: LED indicator
Slide the latching lever to the first position, then press the yellow button with an insulated tool to operate the contact.
Slide the latching lever to the second position. (The contact is now in the locked position.)
6
7
5. Coil Polarity Blank: Standard 1: Reverse polarity (DC coil only) 6. Surge Absorption Blank: Standard D: Surge absorber diode (DC coil only) V: Surge absorber varistor (AC coil only) 7. Internal Connections Blank: Standard 2 or 5: Non-standard connections (Refer to "Terminal Arrangement and Internal Connection (Bottom View)".) 8. Rated Voltage (Refer to "Coil Ratings".)
1
MK-S
Ordering Information
List of Models
Type Terminals Contact form DPDT Standard Models 3PDT Internal connections (See note 3.) Standard Non-standard Standard Non-Standard Standard Non-standard Standard 3PDT Non-Standard Standard Non-standard Standard 3PDT Plug-in DPDT Models with LED Indicator and Diode Non-Standard Standard Non-standard Standard 3PDT Non-Standard Standard Non-standard Standard 3PDT Non-Standard Standard Non-standard Standard 3PDT Non-Standard With mechanical indicator MKS2P MKS2P-2 MKS3P MKS3P-2 MKS3P-5 MKS2PN(1) MKS2PN(1)-2 MKS3PN(1) MKS3PN(1)-2 MKS3PN(1)-5 MKS2P(1)-D MKS2P(1)-D-2 MKS3P(1)-D MKS3P(1)-D-2 MKS3P(1)-D-5 MKS2PN-D MKS2PN-D-2 MKS3PN-D MKS3PN-D-2 MKS3PN-D-5 MKS2P-V MKS2P-V-2 MKS3P-V MKS3P-V-2 MKS3P-V-5 MKS2PN-V MKS2PN-V-2 MKS3PN-V MKS3PN-V-2 MKS3PN-V-5 With mechanical indicator Coil ratings and lockable test button MKS2PI MKS2PI-2 MKS3PI MKS3PI-2 MKS3PI-5 MKS2PIN(1) MKS2PIN(1)-2 MKS3PIN(1) MKS3PIN(1)-2 MKS3PIN(1)-5 MKS2PI(1)-D MKS2PI(1)-D-2 MKS3PI(1)-D MKS3PI(1)-D-2 MKS3PI(1)-D-5 MKS2PIN-D MKS2PIN-D-2 MKS3PIN-D MKS3PIN-D-2 MKS3PIN-D-5 MKS2PI-V MKS2PI-V-2 MKS3PI-V MKS3PI-V-2 MKS3PI-V-5 MKS2PIN-V MKS2PIN-V-2 MKS3PIN-V MKS3PIN-V-2 MKS3PIN-V-5 AC AC DC DC AC/DC AC/DC
DPDT Models with LED Indicator (See note 2.)
DPDT Models with Diode (See note 2.)
DPDT Models with Varistor
DPDT Models with LED Indicator and Varistor
Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications. Example: MKS3P 24 VDC Rated voltage 2. The DC coil comes in two types: standard coil polarity and reverse coil polarity. Refer to Terminal Arrangement and Internal Connections (Bottom View). Example: MKS2PIN1-2 24 VDC Reverse coil polarity 3. Refer to Terminal Arrangement and Internal Connections (Bottom View) for non-standard internal connections.
List of Models (Order Separately)
Item 8-pin Track-mounted Socket 11-pin 8-pin 11-pin Hold-down Clip (For PF083A-E and PF113A-E) Type Model PF083A-E PF113A-E PF083A-D PF113A-D PFC-A1
2
MK-S
Specifications
Ratings
Coil Ratings
Rated voltage 6V 12 V 24 V 100 V AC 110 V 200 V 220 V 230 V 240 V 6V 12 V DC 24 V 48 V 100 V Note: 1. 2. 3. 4. Rated current 50 Hz 443 mA 221 mA 110 mA 26.6 mA 24.2 mA 13.3 mA 12.1 mA 10.0 mA 11.0 mA 224 mA 112 mA 55.8 mA 28.1 mA 13.5 mA 60 Hz 385 mA 193 mA 96.3 mA 23.1 mA 21.0 mA 11.6 mA 10.5 mA 11.5 mA 9.6 mA Coil resistance 3.1 13.7 48.4 760 932 3,160 3,550 4,250 4,480 26.7 107 430 1,710 7,390 15% min. of rated voltage Approx. 1.4 W 80% max. of rated voltage 30% min. of rated voltage at 60 Hz 25% min. of rated voltage at 50 Hz 110% of rated voltage Approx. 2.3 VA at 60 Hz Approx. 2.7 VA at 50 Hz Must operate voltage Must release voltage Max. voltage Power consumption
110 V 12.3 mA 8,960 The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of +15%/-20% for AC rated current and 15% for DC coil resistance. Performance characteristic data are measured at a coil temperature of 23C. The maximum voltage is one that is applicable instantaneously to the Relay coil at 23C and not continuously. For DC-operated Relays with the LED indicator built-in, add an LED current of approx. 5 mA to the rated current.
Contact Ratings
Load Contact mechanism Contact material NO Rated load NC Rated carry current Max. switching voltage Max. switching current Max. switching power NO NC Resistive load (cos = 1) Single AgSnIn 10 A, 250 VAC 10A, 30 VDC 5 A, 250 VAC 5 A, 30 VDC 10 A 250 VAC, 250 VDC 10 A 2,500 VA/300 W 1,250 VA/150 W Inductive load (cos = 0.4)
7 A, 250 VAC
3
MK-S
Characteristics
Contact resistance Operate time Release time Max. operating frequency Insulation resistance Dielectric strength Insulation method Impulse withstand voltage Pollution degree Rated insulation voltage Vibration resistance Shock resistance Endurance 100 m max. AC: 20 ms max. DC: 30 ms max. 20 ms max. (40 ms max. for built-in Diode Relays) Mechanical: 18,000 operations/h Electrical: 1,800 operations/h (under rated load) 100 M min. (at 500 VDC) 2,500 VAC 50/60 Hz for 1 min between coil and contacts 1,000 VAC 50/60 Hz for 1 min between contacts of same polarity and terminals of the same polarity 2,500 VAC 50/60 Hz for 1 min between current-carrying parts, non-current-carrying parts, and opposite polarity Basic insulation 4.5 kV between coil and contacts (with 1.2 x 50 s impulse wave) 3.0 kV between contacts of different polarity (with 1.2 x 50 s impulse wave) 3 250 V Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) Destruction: 1,000 m/s2 (approx. 100 G) Malfunction: 100 m/s2 (approx. 10 G) Mechanical: 5,000,000 operations min. (at 18,000 operations/h under rated load) Electrical: 100,000 operations h. (at 1,800 operations/h under rated load) Operating: -40 to 60C (with no icing or condensation) Operating: 5% to 85%
Failure rate P level (reference value) 10 mA at 1 VDC Ambient temperature Ambient humidity
Weight Approx. 90 g Note: 1. The values given above are initial values. 2. P level: 60 = 0.1 x 10-6/operation 3. Ambient temperature of models with LED indicator is -25 to 60C.
Approved Standards
UL508 (File No. E41515)
Coil ratings Contact ratings Operations 10 A, 250 V AC 50/60 Hz (Resistive) N.O. 10 A, 30 V DC (Resistive) 100,000 contact 7 A, 250 V AC 50/60 Hz (General Use) 10 A, 250 V AC 50/60 Hz (Resistive) N.C. 10 A, 30 V DC (Resistive) 100,000 contact 7 A, 250 V AC 50/60 Hz (General Use)
IEC Standard/TUV Certification: IEC61810-1 (Certification No. R50104853)
Coil ratings 6, 12, 24, 48, 100, 110 VDC 6, 12, 24, 100, 110, 200, 220, 240 VAC N.O. contact N.C. contact Contact ratings Operations 10 A, 250 V AC 50/60 Hz (Resistive) 10 A, 30 V DC (Resistive) 100,000 7 A, 250 V AC 50/60 Hz (General Use) 5 A, 250 V AC 50/60 Hz (Resistive) 5 A, 30 V DC (Resistive) 100,000 7 A, 250 V AC 50/60 Hz (General Use)
6 to 110 VDC 6 to 240 VAC
CSA Standard: CSA Certification by : CSA C22.2 No. 14
Note: When Relays are mounted on the PF083A-E or PF113A-E, the maximum carrying current is 9 A.
Engineering Data
Reference Data
Maximum Switching Power
Switching current (A) 100
Rated Carry Current vs. Ambient Rated Temperature
Rated carry current (A)
50 30 DC resistive load with NO contact 10 AC resistive load with NO contact
10
UL derating curve
5
5 3 DC resistive load with NC contact 1 10 30 AC resistive load with NC contact
AC inductive load (cos = 0.4)
50
100
300
500 1.000
0 -40
-20
0
20
40
60
80
Switching voltage (V)
Ambient temperature (C)
Note: The lower limit of the ambient operating temperature for models with built-in operation indicators is -25C.
4
MK-S
Dimensions
Models without Latching Lever Models with Latching Lever
(Unit: mm)
34.5 max.
34.5 max.
34.5 max.
0.8
52.5 max.
34.5 max.
0.8
52.5 max.
Sockets
See below for Socket dimensions. Socket Maximum carry current Surface-mounting Socket (for track or screw mounting) Finger-protection models 10 A PF083A-E 2 poles PF083A-D 5A PF083A ---
PF113A-E 3 poles
PF113A-E-D
PF113A
Note: Use the Surface-mounting Sockets (i.e., finger-protection models) with "-E" at the end of the model number. When using the PF083A and PF113A, be sure not to exceed the Socket's maximum carry current of 5 A. Using at a current exceeding 5 A may lead to burning. Round terminals cannot be used for finger-protection models. Use Y-shaped terminals.
PF083A-E (Conforming to EN 50022)
Eight, M3.5 x 7 sems 7 4
PF113A-E (Conforming to EN 50022)
Terminal Arrangement
Eleven, M3.5 x 7 sems 7 4
Terminal Arrangement
52 max.
35.4 52 max. 3.5 2 21 max. 35.4
33 41 max.
Mounting Holes
Two, M4 or two 4.5-dia. holes
4
34 42.8 max.
3.5
2 31 max.
Mounting Holes
Two, M4 or two 4.5-dia. holes
330.2
330.2
5
MK-S
PF083A-D
8
PF113A-D
Terminal Arrangement
5.5 24 6 22 5 12 4 14 3 5.5
8
Terminal Arrangement
32 24 21 22 12 87 6 54
4
27 4 27
Eight, M4 screws 7 A2 8 21 1 11 2 A1 Eight, M4 screws 9 10 23 34 A2 11 1 A1 14 31 11
65
Mounting Holes
Two, M4 or two 4.5-dia. hole
65
Mounting Holes
Two, M4 or two 4.5-dia. hole
30 30 38 38
Hold-down Clips
PFC-A1
(2 pieces per set)
4.6
60.8
62
6
4.5
Mounting Tracks
PFP-100N, PFP-50N (Conforming to EN 50022)
PFP-100N2 (Conforming to EN 50022)
16 7.30.15 4.5 350.3 15 25 10 25 1000 (500)* 25 10 25 * 270.15 1 15 25 10 25 10004 25 10 25 15 4.5 350.3 27 24 1 29.2 1.5
* This dimension applies to the PFP-50N Mounting Track.
* A total of twelve 25 x 4.5 elliptic holes is provided with six holes cut from each track end at a pitch of 10 mm.
Mounting Height with Sockets Surface-mounting Sockets
Three poles 87.8 (See note.) 84.3
77.8 (See note.)
Two poles 74.3
PF083A(-E)
PF113A(-E)
Note: PF083A(-E) and PF113A(-E) allow either track or screw mounting.
6
MK-S
Terminal Arrangement and Internal Connection (Bottom View)
Standard Models (AC/DC Coil)
MKS2P(I)
4 3 2 1 8 5 6 7 3 2 1 8
MKS2P(I)-2
4 5 6 7
MKS3P(I)
6
MKS3P(I)-2
6
MKS3P(I)-5
5 6 7 8 9 2 1 11 10
5 4 3 2 1
7 8 9 10 11 4 3 2
5
7 8 9 10
4 3
1
11
Models with LED Indicator (AC Coil)
MKS2P(I)N
4 3 2 1 8 5 6 7
MKS2P(I)N-2
4 3 2 1 8 5 6 7
MKS3P(I)N
6
MKS3P(I)N-2
6
MKS3P(I)N-5
5 6 7 8 9 2 1 11 10
5 4 3 2 1
7 8 9 10 11
4 3 2
5
7 8 9 10
4 3
1
11
Models with Diode (DC Coil: Standard Polarity)
MKS2P(I)N
4 3 2 1 8 5 6 7
MKS2P(I)N-2
4 3 2 1 8 5 6 7
MKS3P(I)N
6
MKS3P(I)N-2
6
MKS3P(I)N-5
5 6 7 8 9 2 1 11 10
5 4 3 2 1
7 8 9 10 11 4 3 2
5
7 8 9 10
4 3
1
11
Models with LED Indicator and Diode (DC Coil: Reverse Polarity)
MKS2P(I)N1
4 3 2 1 8 5 6 7
MKS2P(I)N1-2
4 3 2 1 8 5 6 7
MKS3P(I)N1
6
MKS3P(I)N1-2
6
MKS3P(I)N1-5
5 6 7 8 9 2 1 11 10
5 4 3 2 1
7 8 9 10 11 4 3 2
5
7 8 9 10
4 3
1
11
Standard Models (DC Coil: Standard Polarity)
MKS2P(I)-D
4 3 2 1 8 5 6 7
MKS2P(I)-D-2
4 3 2 1 8 5 6 7
MKS3P(I)-D
6
MKS3P(I)-D-2
6
MKS3P(I)-D-5
6
5 4 3 2 1
7 8 9 10 11 4 3 2
5
7 8 9 10
5 4 3 2 1
7 8 9 10 11
1
11
Models with Diode (DC Coil: Reverse Polarity)
MKS2P(I)1-D
4 3 2 1 8 5 6 7
MKS2P(I)1-D-2
4 3 2 1 8 5 6 7
MKS3P(I)1-D
6
MKS3P(I)1-D-2
6
MKS3P(I)1-D-5
5 6
5 4 3 2 1
7 8 9 10 11 4 3 2
5
7 8 9 10 4 3 2
7 8 9 10
1
11
1
11
Models with LED indicator (DC Coil)
MKS2P(I)N-D
4 3 2 1 8 5 6 7
MKS2P(I)N-D-2
4 3 2 1 8 5 6 7
MKS3P(I)N-D
6
MKS3P(I)N-D-2
6
MKS3P(I)N-D-5
5 6 7 8 9 2 1 11 10
5 4 3 2 1
7 8 9 10 11 4 3 2
5
7 8 9 10
4 3
1
11
7
MK-S
Models with Varistor (AC Coil)
MKS2P(I)-V
4 3 2 1 8 5 6 7
MKS2P(I)-V-2
4 3 2 1 8 5 6 7
MKS3P(I)-V
6
MKS3P(I)-V-2
6
MKS3P(I)-V-5
6
5 4 3 2 1
7 8 9 10 11 4 3 2
5
7 8 9 10
5 4 3 2 1
7 8 9 10 11
1
11
Models with LED indicator and Varistor (AC Coil)
MKS2P(I)N-V
4 3 2 1 8 5 6 7
MKS2P(I)N-V-2
4 3 2 1 8 5 6 7
MKS3P(I)N-V
6
MKS3P(I)N-V-2
6
MKS3P(I)N-V-5
5 6 7 8 9 2 1 11 10
5 4 3 2 1
7 8 9 10 11 4 3 2
5
7 8 9 10
4 3
1
11
Safety Precautions
Refer to Safety Precautions for All Relays.
Safety Precautions for Correct Use
Installation
Mount the MK-S with the marking at the bottom.
Handling
Check the coil polarity of models with built-in operation indicator (DC operation coil) and wire them correctly .
Test Button
Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely. Check that the test button is released before turning ON relay circuits. If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. Use an insulated tool when you operate the test button. Models with test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the Relay is in a complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only the requirements for basic insulation are fulfilled.
8
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
2010.2 In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
http://www.ia.omron.com/
OMRON Corporation
(c)Copyright OMRON Corporation 2010 All Right Reserved.


▲Up To Search▲   

 
Price & Availability of MKS3P-2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X